Telemetry Dashboard
How it is used: monitor channel health, actuate outputs, then execute the next safe step.
TEST FOOTAGE · SEDS UCSD × DISPATCH (YC)
LIVE TELEMETRY replay- T+00:42Ignition stable
- T+01:08Valve lag signature appears
- T+02:11Boundary warning acknowledged
- T+03:37Safe shutdown complete
Hot Fire Frame
SYNCEDLive Frame Source
Connected · rtsp://192.168.2.44:8554/stand2/live-feed
Frame-synced with telemetry markers for ignition, lag signature, and shutdown events.
AERO-STAND-2 Tableau
100 HZ STREAMTank Levels
Pressure Logic Chain
- Pressurant Tank248.0 psia
- LOX Tank119.0 psia
- IPA Tank111.0 psia
- LOX Main79.6 psia
- IPA Main72.9 psia
- Chamber Pressure55.8 psia
- Force Generated8.4 kN
Dense Sensor Grid (Procedural)
1x4 dense cards generated from active sensor catalog for scalability.
Actuation Controls
Run Sharing
My Team Workspace
- Owner TeamPropulsion Test Team
- Shared WithComponent Test Team
- Workspace RoleOwner Workspace
Daqstra Assistant
Safety HUD
- Combustion boundaryPASS
- Purge marginPASS
- Fuel temp windowWATCH
Sequence Studio
Deterministic, step-wise automation with explicit PID config.
Editable Sequence Builder
| # | Step | Duration (s) | Control |
|---|
Device Config
Configure sensor types, ranges, scaling, and calibration behavior before execution.
Setup New Sensor
System Graph Pairing
Link each configured sensor to the factor graph and verify against P&ID context.
Current Config Snapshot
- SensorPT-403
- TypePressure
- Scale0-120 psia
- Nodepressurant-tank
- Firmwarefw1.9.5
- CalibrationPASS
Sensor Registry
| Tag | Type | Unit | Range | Stand | Graph Node | Status |
|---|
Integrations
Map protocol endpoints once and reuse across campaigns.
Protocol Map
Daqstra One calls Strata Edge execution APIs after policy approval.
System factor graph view is in Strata Hub → Mission Board.
Endpoint Health
- modbus://192.168.2.41OK
- tcp://192.168.2.55:7001OK
- opcua://edge-node-7WARN
Run Package Handoff
Edge-generated run package can be downloaded locally or pushed upstream to Strata Hub.
Package Provenance
- Run IDENG-24-051
- Config Hashcfg-v3.2.4
- Sequenceseq-ignite-v2
- Signerj.chen
- StatusReady
Audit + Sharing
Operator-auditable log stream for every command and interlock event.
Latest Events
- 14:22:11 · Connected Modbus endpointINFO
- 14:22:34 · Prime Lines completed in 3.4sPASS
- 14:23:02 · Fuel temp envelope warningWARN
Session Context
Shared With
| Person | Team | Permission | Last Access |
|---|---|---|---|
| M. Ortiz | QA | View + Comment | 14:24:10 |
| K. Patel | Program | View + Export | 14:25:43 |
| S. Rao | Safety | View + Execute | 14:26:31 |
Share Audit
Shared Dashboards
| Dashboard | Mode | Source Run | Access | Last Sync |
|---|---|---|---|---|
| Engine Stand Live Board | LIVE | ENG-24-047 | View + Comment | 14:33:22 |
| ENG-24-047 Post-Test Replay | RECORDED | ENG-24-047 | View + Export | 14:41:05 |